14L 900W Dental Lab Autoclave Steam Sterilizer Sterilization Equipment

Description:Chamber capacity:Ø25×D28CM (Ø9.84×D11.02inch)Inside capacity:14 LiterMaterial:Stainless steel #304Outside Size :46.5*35*36 CMPacking Size :51*39*40 CM G.W:15KGSSterilizer temperature:121℃Sterilize pressure:0.12MpaSterilize time:25Min Power:900WAC110V/8AAC220V/4AAuto supply water system: Manual give the waterSafety valve: automatic discharge in excess of standard valueTemp and Press display:Pressure gaugeDisinfection principle:Uses the vapor power emissions cold air / 2 timesOperation Steps:1.Plug in the power cord 2.Shut exhaust needle valve in the Close (clockwise)° 3.Adding about 800 ml of distilled water. Close the door cover, tight the rotate handle4. Start the timer knob to 121 ℃ position. Sterilization is working.5.Sterilization is complete, please be sure to open the exhaust needle valve firstly (inverse clock direction)6.Wait for the pressure gauge pointer to zero, opened the door cover Caution:Every time sterilization, must add about 800 ml of distilled waterUse a separate socket (confirm the socket of the output voltage)Pressure gauge pointer in the red areas, please be sure to first Open the exhaust steam of the needle valvePacking:main unit 1pcStandard accessories:Plate 3pcs ( Size:21*15.5*2 cm)Shelf 1pcTake Plate tool 1pc steam exhaust pipe 1pc(1 meter length)FDA StatementThe sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.Seller name:DEERBELLCity,State:SHENZHEN,ChinaTelephone number:0755-36925817

Continue reading

14L 900W Dental Lab Autoclave Steam Sterilizer Sterilization Equipment

Description:Chamber capacity:Ø25×D28CM (Ø9.84×D11.02inch)Inside capacity:14 LiterMaterial:Stainless steel #304Outside Size :46.5*35*36 CMPacking Size :51*39*40 CM G.W:15KGSSterilizer temperature:121℃Sterilize pressure:0.12MpaSterilize time:25Min Power:900WAC110V/8AAC220V/4AAuto supply water system: Manual give the waterSafety valve: automatic discharge in excess of standard valueTemp and Press display:Pressure gaugeDisinfection principle:Uses the vapor power emissions cold air / 2 timesOperation Steps:1.Plug in the power cord 2.Shut exhaust needle valve in the Close (clockwise)° 3.Adding about 800 ml of distilled water. Close the door cover, tight the rotate handle4. Start the timer knob to 121 ℃ position. Sterilization is working.5.Sterilization is complete, please be sure to open the exhaust needle valve firstly (inverse clock direction)6.Wait for the pressure gauge pointer to zero, opened the door cover Caution:Every time sterilization, must add about 800 ml of distilled waterUse a separate socket (confirm the socket of the output voltage)Pressure gauge pointer in the red areas, please be sure to first Open the exhaust steam of the needle valvePacking:main unit 1pcStandard accessories:Plate 3pcs ( Size:21*15.5*2 cm)Shelf 1pcTake Plate tool 1pc steam exhaust pipe 1pc(1 meter length)FDA StatementThe sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.Seller name:DEERBELLCity,State:SHENZHEN,ChinaTelephone number:0755-36925817

Continue reading